Codes & Guidelines


Series 750

  • Florida Building Code number FL 12765-R4
  • Not for use in HVHZ.
  • Push-up or electric operation.
  • Maximum opening width is 10’-0”.
  • Maximum opening height is 12’-0”.
  • 26 gauge curtain with windlocks on curtain for opening widths over 6’-0”.

Series 850

  • Miami-Dade County NOA number 15-0312.01
  • For use in Miami-Dade County and Broward County HVHZ.
  • Push-up or electric operation.
  • Maximum opening width is 8’-8”.
  • Maximum opening height is 12’-0”.
  • 24 gauge curtain with windlocks on curtain for all opening widths.

Series 850-S

  • Florida Building Code number FL 12765-R4
  • For use in HVHZ, other than Miami-Dade County.
  • Push-up or electric operation.
  • Maximum opening width is 8’-8”.
  • Maximum opening height is 12’-0”.
  • 26 gauge curtain with windlocks on curtain for all opening widths.

Series 3100

  • Florida Building Code number FL 12765-R2
  • Not for use in HVHZ.
  • Push-up, hand chain or electric operation.
  • Maximum opening width is 18’-0”.
  • Maximum opening height is 18’-0”.
  • 26 gauge curtain with windlocks on curtain for all opening widths.

Series 3400

  • Miami-Dade County NOA number 15-0520.05
  • Push-up, hand chain or electric operation
  • Push-up, hand chain or electric operation.
  • Maximum opening width is 12’-0”.
  • Maximum opening height is 18’-0”.
  • 24 gauge curtain with windlocks on curtain for all opening widths.

Series 3652

  • 26 gauge curtain with windlocks on curtain for all opening widths.
  • Florida Building Code number FL 14425-R2
  • Push-up, hand chain or electric operation.
  • Maximum opening width is 18’-0”.
  • Maximum opening height is 18’-0”.
  • Series 750, 1100, 3100 and 3652 are designed in accordance with the latest editions of ASCE7, International Building Code and Florida Building Code. Doors have been tested to ASTM 330 and see DASMA 108.
  • Series 850 and 3400 is designed to comply with the Miami-Dade County Product Control Division for the High Velocity Hurricane Zone (HVHZ).
  • Series 850-S is designed to comply with the latest edition of the Florida Building Code, including applicable provisions for High Velocity Hurricane Zones (HVHZ). Door has been tested to TAS 201, TAS 202 and TAS 203.